View Basket | Checkout | Items:, Value:
![]() | ![]() | ![]() |
![]() |
|
|
Flow rate up to 2400 L/min (144 m³/hr)
Dynamic head up to 41 m
These pumps are recommended for clean water and fluids that are not chemically aggressive to the pump components.
THEY ARE PRINCIPALLY USED FOR CIVIL, INDUSTRIAL AND AGRICULTURAL APPLICATIONS, WHICH BENEFIT FROM THEIR STURDINESS AND RELIABILITY.
They are manufactured to EN 733 - DIN 24255 standards. Overall dimensions, sizes and positions of suction and delivery ports, support feet and other dimensional characteristics comply with these standards.
Users can be sure these pumps will meet even the most demanding heavy-duty needs and that they can be easily interchanged with other standardized pumps. The design allows dismantling without disconnecting the pump body from the pipeline (back pull-out), making them easy to use in a variety of conditions.
F pumps come in a wide and diverse range.
The wide range makes it easy to select the correct model for each
application. Together with high performance efficiency, this means
big savings in operating costs since these are powerful machines
often intended for continuous duty.
Curve tolerance according to ISO 2548.
The remaining single phase motors and all three phase motors require an adequate external motor protector connected according to current standards.

| PERFORMANCE DATA AT=2900 1/min | |||||||||||||||
| PUMP MODEL | POWER | Q m³/h |
0 | 36 | 48 | 60 | 72 | 84 | 96 | 108 | 120 | 132 | 144 | ||
| Single Phase | Three Phase | KW | HP | l/min | 0 | 600 | 800 | 1000 | 1200 | 1400 | 1600 | 1800 | 2000 | 2200 | 2400 |
| _____ | F 65/160C | 9.2 | 12.5 | Hm | 32 | 32 | 31.8 | 31.5 | 31 | 30 | 29 | 27 | 25 | 22 | |
| _____ | F 65/160B | 11 | 15 | 37 | 36.5 | 36.3 | 36 | 35.5 | 34 | 33 | 31 | 29 | 26 | 23 | |
| _____ | F 65/160A | 15 | 20 | 41 | 40.5 | 40.3 | 40 | 39.5 | 38.5 | 37 | 35.5 | 33.5 | 31 | 28 | |
| H = TOTAL DYNAMIC HEAD IN METRES | |||||||||||||||
| Q = FLOW RATE | |||||||||||||||


| PUMP MODEL | DN1 | DN2 | Dimensions mm | |||||||||||
| Single Phase | Three Phase | a | f | h | h1 | h2 | n | n1 | n2 | w1 | w2 | s | ||
| _____ | F 65/160C | 80 | 65 | 100 | 618 | 360 | 160 | 200 | 295 | 212 | 280 | 47.5 | 47.5 | 14 |
| _____ | F 65/160B | 80 | 65 | 100 | 618 | 360 | 160 | 200 | 295 | 212 | 280 | 47.5 | 47.5 | 14 |
| _____ | F 65/160A | 80 | 65 | 100 | 713 | 360 | 160 | 200 | 295 | 212 | 280 | 47.5 | 47.5 | 14 |