pumpexpress.co.uk

2CP Two Stage Centrifugal Pump Range General Product Description

PK End Suction Pump
Further Product Info

2CP Pump Performance Curve
2CP Pump Performance Data
2CP Pump Dimensions
Get the bigger picture

PERFORMANCE RANGE

Flow rate up to 400 L/min (24 m³/h)
Dynamic head up to 112 m

High efficiency, quiet running pumps with long even curves. Suitable for continuous heavy duty service in domestic, agricultural or industrial applications.

PUMP INSTALLATION AND APPLICATIONS

These pumps are suitable for handling clean water and fluids which are not chemically aggressive to the pump components. They are an obvious choice wherever there is a need for high head values hard to reach with single impeller pumps.

2CP SERIES PUMPS ARE EXTREMELY RELIABLE, SIMPLE TO USE, QUIET AND VIRTUALLY MAINTENANCE-FREE, FINDING MANY USES IN DOMESTIC, CIVIL AND INDUSTRIAL APPLICATIONS, PRESSURE BOOSTING, BOILER FEED, COOLING SYSTEMS AND FIRE-FIGHTING UNITS.

These pumps should be installed in a covered area, protected against the weather.

PERFORMANCE

The wide range of pumps in the 2CP series have the following features:

  • Long even performance curves (high ratio between maximum & minimum head values);
  • High outputs;
  • Flat absorption curves at high delivery rates, preventing motor overloading even during prolonged use;
  • good suction capacities both at low and high delivery rates

Curve tolerance according to ISO 2548.

STRUCTURAL CHARACTERISTICS

  • Cast iron SUCTION BODY with UNI ISO 228/1 gas threaded suction and delivery port.
  • Cast iron DELIVERY BODY with UNI ISO 228/1 gas threaded delivery port.
  • BRASS IMPELLER, centrifugal radial flow type.
  • AISI 316 stainless steel MOTOR SHAFT (AISI 416 up to 0.75 kW).
  • Ceramic and graphite MECHANICAL SEAL
  • MOTOR: pumps are coupled directly to an asynchronous, high efficiency PEDROLLO induction motor of suitable size, which is quiet running, closed and externally ventilated, suitable for continuous duty.
    INSULATION class F (B up to 0.75 kW).
    A thermal cutout relay (motor protector) is incorporated in single phase motors up to 1.5 kW.

The remaining single phase motors and all three phase motors require an adequate external motor protector connected according to current standards

  • PROTECTION IP 44.
    CONSTRUCTION AND SAFETY STANDARDS in compliance with EN 60 335 -1, (IEC 335-1, CEI 61-150), EN 60034-1, (IEC 34-1, CEI 2-3).

 

PERFORMANCE CURVE

PERFORMANCE DATA

PERFORMANCE DATA AT=2900 1/min

PUMP MODEL POWER Q
m³/h
0 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.4 6.0 6.6 7.5 8.4 9.6 10.8 12.0
Single Phase Three Phase KW HP l/min 0 20 30 40 50 60 70 80 90 100 110 125 140 160 180 200
2CPm 25/130 2CP 25/130 0.75 1 Hm 44 40 37 34 30 26 22 18                 
2CPm 25/140H 2CP 25/140H 1.1 1.5 54 53 51 49 46 42 38 34 29  24             
2CPm 25/140M 2CP 25/140M 1.1 1.5 47 46 45.5 44 43 42 41 38 36 34 31 27 22      
2CPm 160/160 2CP 160/160 1.5 2 66 64 6260 57 53 49 44 39.5 35 30            
2CPm 25/160B 2CP 25/160B 1.5 2 58 56 55 54 53 52 50 48 46 44 41 37 33 26     
_____ 2CP 25/160A 2.2 3 68 66.5 66.5 65 63 62 60 58 56 54 51 47 42 35 28  
PUMP MODEL POWER Q
m³/h
0 2.4 3.0 3.6 4.2 4.8 5.4 6.0 6.6 7.5 8.4 9.6 10.8 12.0 15.0 18.0
Single Phase Three Phase KW HP l/min 0 40 50 60 70 80 90 100 110 125 140 160 180 200 250 300
_____ 2CP 32/200C 3 4 Hm 70 66 66.5 65 64 63 62 60 59 56 53 49 45 40    
_____ 2CP 32/200B 4 5.5 85 81 80 79 78 77 76 75 74 72 69 66 62 58 45  
_____ 2CP 32/210B 5.5 7.5 94 94 93.5 93 92 91 90 89 87 85 83 79 75 70 56  
_____ 2CP 32/210A 7.5 10 112 111 110.8 110.5 110.3 110 109 108 107 105 102 99 94 89 74  
PUMP MODEL POWER Q
m³/h
0 6.0 6.6 7.5 8.4 9.6 10.8 12.0 15.0 18.0 21.0 24.0        
Single Phase Three Phase KW HP l/min 0 10 110 125 140 160 180 200 250 300 350 400        
_____ 2CP 40/180C 4 5.5 Hm 64 62 61 60 59 58 56 54.5 49 43 35           
_____ 2CP 40/180B 5.5 7.5 76 73 72.6 72 71 70 69 67.5 64 59.5 54 46        
_____ 2CP 40/180A 7.5 10 88 85 84.6 84 83 82 81 79.5 76 72 67 60        
H = TOTAL DYNAMIC HEAD IN METRES
Q = FLOW RATE

PRODUCT DIMENSIONS

PUMP MODEL DN1 DN2 Dimensions mm

Single Phase

Three Phase

a f h h1 h2 n n1 w1 s
2CPm 25/130 2CP 25/130 1" 74 335 213 89 124 180 145 15 10
2CPm 25/140H 2CP 25/140H 1" 74 356 225 93 132 200 162 23 10
2CPm 25/140M 2CP 25/140M 1" 74 356 225 93 132 200 162 23 10
2CPm 160/160 _____ 1" 84 399 263 110 153 225 185 26 11
_____ 2CP 160/160 1" 84 379 263 110 153 225 185 26 11
2CPm 25/160B _____ 1" 86 401 263 110 153 225 185 26 11
_____ 2CP 25 160B 1" 86 381 263 110 153 225 185 26 11
_____ 2CP 25/160A 1" 86 401 263 110 153 225 185 26 11
_____ 2CP 3/2200C-B 90 476 302 132 170 240 190 41 14
_____ 2CP 32/210A-B 2" 112 570 334 139 195 284 232 25 14
_____ 2CP 40/180C 2" 112 526 334 139 195 284 232 25 14
_____ 2CP 40/180B-A 2" 112 570 334 139 195 284 232 25 14